<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-12 08-27-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 3/5, 34 dBuV R-PCE
Pilot RDS Phase Difference
6.3 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
13 kHz 33 kHz 2894 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,0 dBr -0,71 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 8:27, 12.05.2026
RT
"PETER GABRIEL - SOLSBURY HILL "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 33 kHz MIN: 13 kHz % above 77 kHz: 0,0000 Acquired: 2026/05/12 8:27:53 Total samples: 2894 Equivalent time: 0:02:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: -0,4 dBr MIN: -1,0 dBr AVE: -0,71 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2026/05/12 8:27:52) 08:14 08:16 08:18 08:20 08:22 08:24 08:26 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality